1.linux 虚拟盘

2.英特尔快速存储技术在哪里下载啊?

3.Intel(R) Rapid Storage Technology的作用

4.如何在raid上安装win7

5.AMD的南桥驱动是什么东西?

6.安装新硬盘后/如何安装intel快速存储驱动

7.我现在是用 intel ich10R的芯片组组了raid0 现在想换成 AMD的, 能不能通用啊

_intel ich9r raid驱动

一、准备AHCI驱动

1、、安装AHCI驱动之前,请先确认桌面上、系统盘没有重要的东西需要备份,因为如果安装失败可能导致系统无法启动,除非你有第二系统或应对修复方法。

2、准备AHCI驱动:

A、对于台式机用户,主板的驱动光盘中一般都有这个东西,笔记本用户就不一定,留意一下驱动盘中是否有类似Intel Matrix Storage Manager Driver、Matrix Storag、SATA Driver、AHCI字样的驱动软件。

B、如没有随机驱动盘就到找,一定要注意该AHCI驱动的支持的Windows或Linux操作系统版本。

C、实际上AHCI驱动的通用性很强,只需要按照芯片组(AMD、INTEL、NV...,具体可在笔记本或主板说明书里查看)到网上都能找到,可以查看驱动包中的类似iaAHCI.inf文件中,AHCI驱动下载一文中也有ThinkPad Intel(R) Matrix Storage Manager Driver(Win 2k_XP)驱动,不过该驱动是2006年的,适合一些老主板:

iaStor_ICH7DH = "Intel(R) 82801GR/GH SATA RAID Controller (Desktop ICH7R/DH)"

iaAHCI_ICH7R = "Intel(R) 82801GR/GH SATA AHCI Controller (Desktop ICH7R/DH)"

iaAHCI_ICH7M = "Intel(R) 82801GBM SATA AHCI Controller (Mobile ICH7M)"

iaStor_ICH6R = "Intel(R) 82801FR SATA RAID Controller (Desktop ICH6R)"

iaAHCI_ICH6R = "Intel(R) 82801FR SATA AHCI Controller (Desktop ICH6R)"

iaAHCI_ICH6M = "Intel(R) 82801FBM SATA AHCI Controller (Mobile ICH6M)"

iaStor_ICH5R = "Intel(R) 82801ER SATA RAID Controller (Desktop ICH5R)"

iaStor_ICH5RHR = "Intel(R) 6300ESB SATA RAID Controller"

虽然很多同类型AHCI驱动可以通用的,一方面使用通用驱动会面临着AHCI设备编号的确定问题(感觉总是跟设备管理器里显示的ATA设备编号是加1连号,网上说的设备管理器显示AHCI设备号,那是装好之后才有的,无参考意义,所以只能从官方驱动(*.inf和*.oem)结合本机设备管理器或其它渠道获取),另一方面版本不同支持情况也不同,一次装错了可能系统就不能启动了。

D、天缘还是建议您最好使用官方的AHCI驱动,下载后安装或解压后大都只是个普通的驱动包,需要手动安装。下面是天缘从DELL下载的E5400 AHCI驱动包(支持Windows XP,点击本地下载)里支持情况(大家可根据自己机子芯片组型号确定是否可以使用此驱动包):

; iaAHCI.inf

iaAHCI_ESB2 = "Intel(R) ESB2 SATA AHCI Controller"

iaAHCI_ICH7RDH = "Intel(R) ICH7R/DH SATA AHCI Controller"

iaAHCI_ICH7MMDH = "Intel(R) ICH7M/MDH SATA AHCI Controller"

iaAHCI_ICH8RDHDO = "Intel(R) ICH8R/DH/DO SATA AHCI Controller"

iaAHCI_ICH8MEM = "Intel(R) ICH8M-E/M SATA AHCI Controller"

iaAHCI_ICH9RDODH = "Intel(R) ICH9R/DO/DH SATA AHCI Controller"

iaAHCI_ICH9MEM = "Intel(R) ICH9M-E/M SATA AHCI Controller"

iaAHCI_ICH10DDO = "Intel(R) ICH10D/DO SATA AHCI Controller"

iaAHCI_ICH10R = "Intel(R) ICH10R SATA AHCI Controller"

; iaStor.inf

iaStor_ESB2 = "Intel(R) ESB2 SATA RAID Controller"

iaStor_ICH7RDH = "Intel(R) ICH7R/DH SATA RAID Controller"

iaStor_ICH7MDH = "Intel(R) ICH7MDH SATA RAID Controller"

iaStor_ICH8RICH9RICH10RDO = "Intel(R) ICH8R/ICH9R/ICH10R/DO SATA RAID Controller"

iaStor_ICH8MEICH9ME = "Intel(R) ICH8M-E/ICH9M-E SATA RAID Controller"

注意:如果使用的是驱动光盘自带的AHCI(也有说是SATA驱动的,天缘的台式机技嘉主板就是),该驱动的提取方法最好先参阅一下主板说明书,也可能是在DOS下提取也可能可以在Windows上提取。如果驱动光盘有软件安装管理界面的,可以直接在管理界面中提取。 下面来看一下安装方法。

二、在操作系统安装前加载AHCI驱动

这个方法有点麻烦,除非安装的系统是修改版的已经集成了AHCI驱动,否则需提前把AHCI驱动拷贝到软盘或U盘中,手动安装AHCI驱动方法(SATA RAID驱动加载方法类似):

1、BIOS设定启用AHCI, 几种最常用的BIOS设置方法综合。

2、准备好存有SATA AHCI驱动的磁盘。

3、开机启动Windows XP安装(光盘引导安装或硬盘安装....具体参考博客上文章),当看到Press F6 if you need to install a third party SCSI or RAID driver信息时,立即按下F6键。

4、插入AHCI驱动程序,并按下S键,如果安装程序识别出你的驱动盘,会自动提示出安装选单。

5、请注意选择x86还是x64平台驱动,选择后回车即可安装AHCI驱动,完成后会自动回到Windows XP的安装界面,Windows XP SP3安装教程(图)。

如果是Vista和Windows 7系统,我们可以在安装界面中看到加载驱动程序这样的提示时,点击或选中并回车,即可看到驱动安装界面,插入驱动盘即可安装。

三、在操作系统安装后安装AHCI驱动

该情况在Windows XP下最常见,因为如果开启AHCI,未集成AHCI驱动的Windows XP安装程序会直接蓝屏,无法进入安装界面的,所以要么是参照上文的方法先加载AHCI驱动,要么就是先把BIOS中的SATA MODE设置为ATA MODE或非AHCI的兼容MODE,然后安装完Windows XP后再进行更新AHCI驱动。

安装警告:如果AHCI驱动安装错误或失败,将可能导致系统无法启动,天缘建议你安装前最好把系统盘(包括桌面、我的文档)中的重要内容先行备份后再进行AHCI驱动安装,或者你确认有第二系统或WINPE、启动修复盘等应对措施。

下面就以Windows XP为例进行图解,Vista情况请类似参考文末补充部分。

1、控制面板——系统——硬件选项卡——设备管理器,如下图,天缘机子是设成ATA模式安装的Windows XP,在IDE ATA/ATAPI控制器中选中当前控制器鼠标右键更新驱动程序。

2、欢迎使用硬件更新向导,选择否。

3、选择从列表或指定位置安装(高级),点击下一步。

4、下一步选择不要搜索。要自己选择要安装的驱动程序。

5、选中标准双通道PCI IDE控制器,然后点击下一步。

一定要先装标准双通道PCI IDE控制器驱动,先把控制器恢复到初始状态(如果IDE ATA/ATAPI控制器已经有了这个"标准双通道PCI IDE控制器"条目,则不需要再次安装,可以直接从选择下图的“从磁盘安装”按钮,不要从原ATA驱动直接更新成新AHCI驱动,否则可能无法继续安装而直接蓝屏。

6、安装好标准双通道PCI IDE控制器驱动之后,在标准双通道PCI IDE控制器上鼠标右键,选择更新驱动程序用上文同样步骤,再次到达步骤5,并选择从磁盘安装。

7、选择从磁盘安装后,弹出浏览窗口,点击浏览按钮。

8、选中AHCI驱动,下面还有一个iaStor不用管,选中iaAHCI后会自动把驱动支持情况列出来。

9、点击打开后,一定要选择对应型号的AHCI控制器驱动(拉动滚动条可以看到支持列表。

10、安装时,如果遇到警告,点击确定即可。

11、安装完成后,重启电脑,把BIOS中的SATA MODE设置为AHCI模式,然后再重启电脑,AHCI驱动安装完成,如如果Windows XP无法启动进入,说明AHCI驱动安装的有问题,只能先把BIOS再改回去,要么重装系统,要么使用修复盘进行修复,重新检查安装步骤、驱动版本是否对应等,然后重新安装。

linux 虚拟盘

你的主板是?INTEL?6?Series?芯片组,对应的设备是:

Desktop/Workstation/Server?Express?Chipset?SATA?AHCI?Controller

应该选用的AHCI驱动版本为:11.2.0.1006?或更高版本。

官方称呼为:Intel Rapid Storage Technology 驱动,我们一般称为 AHCI 驱动。

Intel Rapid Storage Technology 分两部分:

AHCI模式: 在AHCI模式下,机械硬盘小文件读写比传统IDE模式0%,固态硬盘效果更明显。

RAID模式: 也叫磁盘阵列,一般用户根本用不到。这里不做说明。

Intel(R) 5 Series:H55 H57 P55

Mobile Express: 笔记本芯片组

ICH7: G41 P43

ICH9: P43 G43

ICH10: P45

Desktop/Workstation/Server?Express: 台式机、服务器、工作站芯片组的意思,也可以理解为other 芯片组。

英特尔快速存储技术在哪里下载啊?

一.迅闪LINUX虚拟磁盘安装、配置

a.安装:

 条件:只能接一块做装系统的硬盘(pata或sata不限)。

 机器从光驱启动,到引导画面的时候,直接按回车即可。

 安装可能遇到问题:

1) 系统找不到光驱驱动器驱动或光盘光驱有问题。        解决方法:1.光盘有问题,重刻光盘。

`` 2.如果用的pata 的光驱,换sata的光驱测试。

3.到的别的机器先把硬盘装好系统,然后把硬盘 换到这台机器上来.

2)系统没有找到硬盘接口驱动或硬盘有问题。 

确定不是硬件问题后,换sata的硬盘测试。

设置root用户密码  输入两次密码,next 即可安装配置,后面全自动安装后重启动

b第一次配置:

安装好系统重起后,到Linux 系统的登录界面,用户是root,密码是刚刚安装Linux 系统的时候输入的root 用户密码。

第一次启动系统的时候会弹配置网络的图形界面,配置网络信息:

1.Linux 的网卡标识(像windows的“本地连接”)一般是eth0(第一块网卡),eth1(第二块网卡),eth2(第三块网卡)

2.网卡的状态的查看:

ethtool 网卡标识,例如:ethtool eth0Speed:1000Mb/s 是当前的网卡有接入速度。

只有一块网卡时,根据向导给eth0配置ip,掩码,网关,dns.

如果有二块网卡,请把两块网卡IP设置在不同的网段里面,不然会导致网络不通,如:

  eth0 192.168.0.1 255.255.0.0

eth1 10.0.0.1 255.255.0.0

这样网络就配置好了,输入poweroff,关机。接上做虚拟盘用的硬盘和阵列卡,阵列卡要做阵列后开机。

c. web 后台配置  a.WEB浏览器打开WEB后台地址://您的Linux 虚拟盘服务器IP,首次登录的在用户名为admin,密码为空,登录后,会提示您修改密码。b、 建立磁盘阵列

  如果您是用单块盘做虚拟盘的话,就跳过建立阵列的步骤,直接看虚拟盘服务设置。

1)硬阵列驱动加载:

如果您的服务器没有找硬阵列驱动,可以在RAID配置中,选择RAID卡驱动然后点保存,即可安装驱动,等一分钟过后,重起服备器生效。您也可以在WEB管理上上重起服务器,在系统工具中的重起主机可实现该功能。

2)软阵列设置:

在RAID配置中的软RAID配置可以自动创建软阵列。选择要做软阵列的硬盘,点创建按钮,即可现实软阵列的组建,如果想撤销,把先前做软阵列的硬盘上勾去掉,点撤销即可删除这个软阵列。

c 虚拟盘服务设置

  1) 选择作为虚拟盘的母盘:如果是软阵列,应该是/dev/md0。

注意:如果您用的是SATA硬盘,但是在这里显示是/dev/hdX设备,正常的应该是/dev/sdX设备,您可以在CMOS设置里面修改一个SATA 的兼容模式,使之为/dev/sdX,,不然硬盘的速度会很慢。

2) 虚拟盘最大缓存:建议用2000M

3) 通信IP:用于控制虚拟盘服务的机器的IP地址,一般为迅闪服务端IP地址。

4) 超级IP:用于更新虚拟盘数据的机器的IP地址。一般为迅闪服务端IP地址。输入好上面的信息后,在虚拟盘服务管理里面,点启动,即可启动虚拟盘服务,这时有在客户机用ISCSI客户端就可以连接Linux 虚拟盘服务器了。ISCSI客户端的安装

d 网卡绑定

  如果您的服务器上有多块网卡的话可以做网卡的绑定,可以提高虚拟盘的性能。

1) 选择要绑定的网卡,输入绑定后的IP地址和子网掩码,然后点保存,重起服务器生效。2) 要解除网卡绑定时,把先前做网卡绑定的网卡上的勾去掉,点保存,然后在网络设备配置中为每个网卡的设IP地址和子网掩码,点保存,重起服务器生效。g 日常维护

  1) 任务:因为每个网吧的情况都不一样,有网吧Linux 虚拟盘服务器一年不重起可以连续工作正常,少数网吧由于软硬件有兼容问题。

2) 所以我们提供了可选的定时重起虚拟盘服务和服务器系统,它们分别在服务配置和系统工具的自动重启中设置的。

2) 系统监控:在系统工具的系统监控页面中,可以看到虚拟盘服务器系统上的各种实时信息。如(虚拟盘的连接数,CPU利用情况,网络利用情况等)。二.ISCSI客户端安装设置与要点。

a)迅闪服务端的双网卡的问题.

迅闪服务端使用双网卡的时候两块网卡时,一定要指定从那块网卡开连接,不然如果是用非超级IP来Linux 虚拟盘的话,那么写操作将不会被保存.

打开微软的iscsi客户端,添加Linux 服务器IP地址.

b)关于克隆系统后部分机器连不上 Linux 虚拟盘问题的解决方法(手动也连不上的问题).

先看下报什么错,手动把iscsi客户端里面的IP删除了,然后手动添加LINUX服务器IP,这时应该会报错上面报错是iscsi客户端连接Linux 虚拟盘服务器时,验证失败,这个错误是由于部分机器的iscsi节点名的重复的情况

可以General 选项卡中修改node name 保证每台机器不一样.也可以用批处理来实现.

hostname >%temp%/hostname.txt

for /f %%a in (%temp%/hostname.txt) do iscsicli NodeName %%a

del /f %temp%/hostname.txt把这个批处理加到迅闪服务端的开机执行中,就不要一台台机器改了.c) iscsi客户端添加时IP报错,iscis客户端安装不正常,或有些系统服务被禁用,请重安装下客户端.d)下面的错误,是不能连接到服务器,试ping 下虚拟盘服务器,如果能ping 虚拟盘服务器,在虚拟盘系统下用

三.虚拟盘服务器回写设置:

1.给系统添加一块专门做回写的硬盘,fdisk -l 看下那块硬盘是那个块设备,比如是/dev/sdc。

2.给这个盘分区格式化,用fdisk 把 /dev/sdc里面的所有的分区全部删除,然后建一个ext3分区并格式化它。

Linux 下面的命令行:

fdisk /dev/sdc

d

.....

wmkfs.ext3 /dev/sdc1如果提示/dev/sdc1没有找到,请重启下系统

3.编辑fstab文件挂载分区。

Linux 下命令操作:

vi /etc/fstab/dev/VolGroup00/LogVol00         / ext3 defaults 1 1

LABEL=/boot /boot ext3 defaults 1 2

tmpfs /dev/shm tmpfs defaults 0 0

devpts /dev/pts dmpevptsgid=5,mode=620  0 0

sysfs /sys sysfs defaults 0 0

proc /proc proc defaults 0 0

/dev/VolGroup00/LogVol01 swap swap defaults 0 0/dev/sdc1  /tmp/iscsi ext3 defaults 0 0 注:添加该行mount -a

4.重启服务器生效四.Linux 虚拟盘服务器的群集.

不需要同步群集服务器 的那个小程序.

第一步.如果你用两台Linux服务器服务器做群集的话,把这两台机器的超级IP能设成迅闪服务端的IP.

第二步.在迅闪服务端,用iscsi客户端分别连两台Linux 服务器,出盘X,Y,必须同时能出盘.

第三步.在迅闪服务端的系统设置->虚拟磁盘->linux 虚拟磁盘,添加这两台服务器.指定盘符X(主虚拟盘),Y.

三层下载游戏目录指定X就可以了,Y盘会自动同步过去的.迅闪服务端的更新日志:

/log/ UpdateS.log 同步游戏文件日志

/log// HtUpdaterLog.ini 已经完成游戏日志.五.Linux 虚拟盘相关的配置文件,和状态文件.

查看方法:

cat 文件名 |more 注:加|more 可以分屏显示.

vi 文件名 注:可以编辑查看

或用winscp 登录到Linux 服务器上查看编辑.

1.Linux虚拟盘服务配置文件.

基本配置:/etc/ietd.conf  下面是该文件的内容# Example iscsi target configuration

#

# Everything until the first target definition belongs

# to the global configuration.

# Right now this is only the user configuration used

# during discovery sessions. "IncomingUser" specifies credentials the

# initiator has to provide - several of these are supported. If mutual

# CHAP shall be employed, "OutgoingUser" specifies the user/pass

# combination the target will provide - only one is supported.

# Lee them alone (keep them commented out) if you don?6?5t want to use

# authentication for discovery sessions.#iSNSServer 192.168.1.16

#iSNSAccessControl No#IncomingUser joe secret

#OutgoingUser jack 12charsecret# Targets definitions start with "Target" and the target name.

# The target name must be a globally unique name, the iSCSI

# standard defines the "iSCSI Qualified Name" as follows:

#

# iqn.yyyy-mm.<reversed domain name>[:identifier]

#

# "yyyy-mm" is the date at which the domain is valid and the identifier

# is freely selectable. For further details please check the iSCSI spec.MaxVolume 2000    注:客户机缓存大小

Target .hintsoft.net:172.17.11.56 注:.hintsoft.net:172.17.11.56 是Target 名称

# Users, who can access this target. The same rules as for discovery

# users ly here.

# Lee them alone if you don?6?5t want to use authentication.

#IncomingUser joe secret

#OutgoingUser jim 12charpasswd

# Logical Unit definition

# You must define one logical unit at least.

# Block devices, regular files, LVM, and RAID can be offered

# to the initiators as a block device.

Lun 0 Path=/dev/hdd,Type=fileio     注: /dev/hdd 做虚拟盘用的硬盘,也可以是分区,如/dev/hdd1

# Alias name for this target

# Alias Test

# various iSCSI parameters

# (not all are used right now, see also iSCSI spec for details)

MaxConnections 1

InitialR2T Yes

ImmediateData No

MaxRecvDataSegmentLength 8192

MaxXmitDataSegmentLength 8192

MaxBurstLength 262144

FirstBurstLength 65536

DefaultTime2Wait 2

DefaultTime2Retain 20

MaxOutstandingR2T 8

DataPDUInOrder Yes

DataSequenceInOrder Yes

ErrorRecoveryLevel 0

HeaderDigest CRC32C,None

DataDigest CRC32C,None

# various target parameters

Wthreads 82.通信IP和超级IP的配置文件

/etc/socketip

这个文件很简单,格式:

通信ip,超级ip3.Linux虚拟盘服务的状态文件

tid:1

write:disk

name:.hintsoft.net:172.17.11.56 注:Target 名称

SessionCounts:1

MaxSessions:0

MaxVolume:2000M 注:缓存大小 2000M

HasSuperIP:YES

SuperIP:172.17.11.58 注:超级IP

sid:281475899523136 initiator:iqn.1991-05.microsoft:server-50

cid:1 ip:172.17.11.50 state:active hd:crc32c dd:crc32c                  注:iscsi客户端的连接信息,iqn.1991-05.microsoft:server-50该客户端的节点名.六.关于阵列卡驱动问题.WEB后台的驱动列表是针对 RedHat Enterprise Linux 5 中没有驱动而添加的.因为它已经自带很多驱动.

Intel ICH6 Raid controller 可针对 intel ich5 ich6 ich7 系统主板可以,关于intel s3000的主板要

在主板的bios设置中把raid类型改成lsi,就可以用这个来驱动.

Intel ICH9(R) Raid controller intel ICH9(R) 的驱动,主要是用于intel S5000 的主板.七.关于Linux 服务器死机问题

1.首先要检查硬件是否有问题,硬件的温度过高等原因.

2.建议做虚拟服务器的内存用相同颗粒、相同品牌的单面内存.

3.官方正在找Linux 内核出错的原因.

4.把客户机的回写到其它硬盘上.(前面有说明)

Intel(R) Rapid Storage Technology的作用

到Intel官方网站下载(输入你电脑主板芯片组的名称,找到芯片组后打开"支持"选项卡,然后下载驱动;硬件或软件不受支持是木有办法装的,芯片组驱动不装也木有办法;单块硬盘装这个没什么用处)

还是附个下载地址吧(://downloadmirror.intel/20624/a08/iata_cd_10.8.0.1003.exe),我电脑的芯片组是Intel H61的,可以装(支持的硬件/软件配置见下)。

----------------------------------------------------------------

支持的操作系统

■ Microsoft Windows* XP Professional

■ Microsoft Windows* XP Professional 64-bit Edition

■ Microsoft Windows* XP Home

■ Microsoft Windows* XP Media Center Edition 2004

■ Microsoft Windows* XP Media Center Edition 2005

■ Microsoft Windows* Server 2003

■ Microsoft Windows* XP

■ Microsoft Windows* XP 64-bit Edition

■ Microsoft Windows* Server 2003 Enterprise x64-bit Edition

■ Microsoft Windows* Server 2003 Standard x64-bit Edition

■ Microsoft Windows* Vista

■ Microsoft Windows* Vista x64-bit Edition

■ Microsoft Windows* Server 2008

■ Microsoft Windows* Server 2008 x64-bit Edition

■ Microsoft Windows* 7

■ Microsoft Windows* 7 x64-bit Edition

支持的英特尔? 芯片组

■ 英特尔? 台式机/工作站/服务器高速芯片组

■ 英特尔? 移动式高速芯片组

■ 英特尔? 3 系列芯片组

■ 英特尔? 4 系列芯片组

■ 英特尔? 5 系列芯片组

■ 英特尔? 3400 系列芯片组

■ 英特尔? PM55/HM57/PM57/QM57/QS57 高速芯片组

■ 英特尔? H57/P55/P57/Q57 高速芯片组

■ 移动式英特尔? 965 高速芯片组家族

■ 英特尔? 965 高速芯片组

■ 英特尔? 5000P 芯片组

■ 英特尔? 5000V 芯片组

■ 英特尔? 5000X 芯片组

■ 英特尔? 5X 高速芯片组

■ 英特尔? 955X 高速芯片组

■ 英特尔? 945X 高速芯片组

■ 移动式英特尔? 945 高速芯片组家族

■ 英特尔? E7230 芯片组

支持的控制器集线器

■ 英特尔? 台式机/工作站/服务器高速芯片组 SATA RAID 控制器集线器

■ 英特尔? 移动式高速芯片组 SATA RAID 控制器集线器

■ 英特尔? 台式机/工作站/服务器高速芯片组 SATA AHCI 控制器集线器

■ 英特尔? 移动式高速芯片组 SATA AHCI 控制器集线器

■ Intel? 5 Series SATA RAID 控制器集线器

■ Intel? 5 Series/3400 Series SATA RAID 控制器集线器

■ Intel? 5 Series/3400 Series SATA AHCI 控制器集线器

■ Intel? 5 Series 4 Port SATA AHCI 控制器集线器

■ Intel? 5 Series 6 Port SATA AHCI 控制器集线器

■ 英特尔? ICH10DO SATA AHCI 控制器集线器

■ 英特尔? ICH10D SATA AHCI 控制器集线器

■ 英特尔? ICH10R SATA AHCI 控制器集线器

■ 英特尔? ICH9M-E SATA AHCI 控制器集线器

■ 英特尔? ICH9M SATA AHCI 控制器集线器

■ 英特尔? ICH9R SATA AHCI 控制器集线器

■ 英特尔? ICH7MDH AHCI/RAID 控制器集线器

■ 英特尔? ICH7M SATA AHCI 控制器集线器

■ 英特尔? ICH7R/7DH SATA AHCI/RAID 控制器集线器

如何在raid上安装win7

Intel Rapid Storage Technology(英特尔快速存储技术)为配备 SATA 磁盘的台式机、移动电脑和服务器平台系统提供更高的性能和可靠性。当使用一个或多个 SATA 磁盘时,可因性能提高及耗电降低而获益。使用多个磁盘时,可增强对磁盘故障时数据丢失的保护。

扩展资料:

英特尔快速存储技术允许在单一阵列上创建两个独立的 RAID 卷。第一个卷占用阵列的一部分,留下空间供第二个卷使用。 随卷的类型不同,阵列可由两个至六个 SATA磁盘组成。英特尔快速存储技术为串行 ATA AHCI 和 RAID 子系统提供增强的管理能力和详细的状态信息。

只有硬盘开启了ACHI模式或者组了RAID的人才需要用到这个英特尔快速存储技术,平时一般是不需要使用英特尔快速存储技术。

AMD的南桥驱动是什么东西?

首先进入主板BIOS,在硬盘模式里,把硬盘的工作模式改为RAID,即开启主板RAID功能。注意要连接两块及以上硬盘,但要为2的倍数。保存CMOS设置,重启。

开启主板RAID功能之后,开机按Ctrl+I组合键,进入RAID配置窗口,由于是在主板BIOS里操作,因此没有鼠标可以用,只能用键盘来完成操作。选择“ Creat new array(新建RAID阵列) ”,在“ Level ?”里选RAID0,也就是速度最快的阵列。完成之后存盘退出,在自检阵列时会有下图的提示。

一块迈拓160G与一块希捷250G组成的RAID0阵列,组完后大小是305G。不同硬盘组阵列有个规律,就是大适应小,快适应慢。也就是说组RAID的大小与容量较小的硬盘为准,速度快的以慢的为准。一块160G的与一块250G的当然在把250G的算成160G的,组完后大小是160 * 2,也就是320G,格式化完刚好是305G,接下来放入windows7系统盘到光驱里,重启,用光盘引导启动。

出现安装界面之后就不用愁了,接下来就全部的中文提示,跟据自己的需要点下一步就行了。值得注意的是在南桥芯片从ICH9以后都不在集成IDE控制器,也就是说IDE接口不是原生的,而是通过一个芯片控制的,而南桥直接控制这个芯片来达到控制光驱及其它IDE设备的目的。既然不是原生的IDE设备,那么在装系统时很可能需要额外装光驱的驱动,也就是IDE控制器的驱动。

通过查询得知,使用的主板为P35+ICH9R芯片组,IDE控制器的型号为JMicron 363,于是到主板官方网站下载了相应的驱动解压到了U盘中,并选择,成功的安装了DVD驱动器的驱动。经过多次实验得知,非原生的IDE控制器如果系统不自带驱动的话,那就必需要装,不然系统无法继续安装。?接下来系统开始解压文件,并可以看到下面的安装进度条。

安装完成,看窗口切换的效果,按快捷键win+Tab。

安装新硬盘后/如何安装intel快速存储驱动

南桥驱动是指南桥芯片的驱动程序。

南桥(英语:Southbridge)是基于个人计算机主板芯片组架构中的其中一枚芯片。南桥设计用来处理低速信号,通过北桥与中央处理器联系。

各芯片组厂商的南桥名称都有所不同,例如英特尔称之为输出/输入控制器中心(Input/Output Controller Hub,ICH),NVIDIA的称为MCP,ATI的称为IXP/SB。AMD也开始纳入Fusion APU,并给予FCH这个标记,或称Fusion控制器中心,代表其南桥芯片。

但在部分的芯片组架构中,会将南桥的功能与北桥集成在一起;或者将部分功能移到北桥,而部分的南桥功能则删除,将被删除的接口功能使用额外独立的芯片组提供功能。这样使得整个芯片组架构中只会有单一芯片,而不会另外的有南桥芯片。

驱动程序一般指的是设备驱动程序(Device Driver),是一种可以使计算机和设备进行相互通信的特殊程序。相当于硬件的接口,操作系统只有通过这个接口,才能控制硬件设备的工作,如某设备的驱动程序未能正确安装,便不能正常工作

。因此,驱动程序被比作“?硬件的灵魂”、“硬件的主宰”、和“硬件和系统之间的桥梁”等。

扩展资料:

作用

南桥芯片负责I/O总线之间的通信,如PCI总线、USB、LAN、ATA、SATA、音频控制器、键盘控制器、实时时钟控制器、高级电源管理等,这些技术相对来说比较稳定,所以不同芯片组中南桥芯片可能是一样的,不一样的只是北桥芯片。

所以主板芯片组中北桥芯片的数量要远远多于南桥芯片。例如早期英特尔不同架构的芯片组Socket 7的430TX和Slot 1的440LX其南桥芯片都用82317AB,而近两年的芯片组Intel945系列芯片组都用ICH7或者ICH7R南桥芯片,但也能搭配ICH6南桥芯片。

百度百科-南桥

百度百科-驱动程序

我现在是用 intel ich10R的芯片组组了raid0 现在想换成 AMD的, 能不能通用啊

Intel Rapid Storage Technology(简称IRST)又称英特尔快速存储技术,早期的版本称Intel Matrix Storage Manager(简称IMSM)。该程序整合了磁盘管理程序控制台及SATA、AHCI、RAID驱动程序,主要用于Intel芯片组的磁盘管理、应用支持、状态查看等应用。?

提示:?

默认条件下,该软件可无需安装。如果因为工作需要或其它需求需要安装时,计算机的磁盘控制器模式必须为AHCI模式,才能正常安装。

操作步骤:

1、下载IRST程序后,使用第三方解压缩软件解压,执行解压后的Install目录下的Setup.exe可执行文件。具体如下图所示:

2、在弹出的对话框中,点击下一步(N)按钮。如下图所示:

3、请仔细阅读警告信息,一旦安装后磁盘控制器的驱动程序将无法卸载。此时可直接点击下一步(N)按钮。如下图所示:

4、接下来,请认真阅读许可协议。如确认无误,请点击是(Y)按钮继续。如下图所示:

5、此时将列出系统要求和一些安装信息,可以直接点击下一步(N)按钮。如下图所示:

6、安装程序将自动进入安装过程。稍等片刻完成后,请点击下一步(N)按钮。如下图所示:

7、当安装完毕后,程序需要重新启动计算机。请保存当前正在运行的工作内容,然后点击完成(F)按钮,重新启动计算机。如下图所示:

8、安装完成后,开机进入系统时将自动启动英特尔(R)快速存储技术程序,可在右下角的任务栏托盘区域双击运行。

支持的RAID控制器:

Intel(R) Desktop/Workstation/Server Express Chipset?SATA?RAID Controller

Intel(R) Mobile Express Chipset SATA RAID Controller

Intel(R) ESB2 SATA RAID Controller

Intel(R) ICH7MDH SATA RAID Controller

Intel(R) ICH7R/DH SATA RAID Controller

支持的AHCI控制器:

Intel(R) Desktop/Workstation/Server Express Chipset SATA AHCI Controller

Intel(R) Mobile Express Chipset SATA AHCI Controller

Intel(R) 5 Series/3400 Series SATA AHCI Controller

Intel(R) 5 Series 4 Port SATA AHCI Controller

Intel(R) 5 Series 6 Port SATA AHCI Controller

Intel(R) ICH10D/DO SATA AHCI Controller

Intel(R) ICH10R SATA AHCI Controller

Intel(R) EP80579 SATA AHCI Controller

Intel(R) ICH9M-E/M SATA AHCI Controller

Intel(R) ICH9R/DO/DH SATA AHCI Controller

Intel(R) ICH8M-E/M SATA AHCI Controller

Intel(R) ICH8R/DH/DO SATA AHCI Controller

Intel(R) ESB2 SATA AHCI Controller

Intel(R) ICH7M/MDH SATA AHCI Controller

Intel(R) ICH7R/DH SATA AHCI Controller

支持的Windows操作系统:

Windows XP 32Bit & 64Bit

Windows 2003 32Bit & 64Bit

Windows Vista 32Bit & 64Bit

Windows 7?32Bit & 64Bit

Windows Server 2008 32Bit & 64Bit

Windows Server 2008 R2 64Bit

d分区,但是最大的启动分区只能是2TB。

如果想要启动分区大于2TB,只能使用GPT模式(GUID Partition Table)而不能使用MBR模式(Master Boot Record)。问题是GPT是不可以直接启动的,除非你的主板支持UEFI(Unified Extensible Firmware Interface)BIOS。

如果你的主板没有UFEI功能的话只能取建立两个小于2TB raid 阵列的方法来绕过ICH10R的芯片限制。

按ctrl-I后,在intel Raid 设置中可以先创建一个1TB的raid 0来安装操作系统,再创建一个2TB的raid 0来存放数据。

这样的话在Raid设置里你可以看见那个1TB的raid 0会显示bootable,在电脑BIOS的启动顺序里才能看见。(显示为intel raid)

Win7 RTM 应该原生能够支持ICH10R的,不用装驱动,万一在安装的时候看不见硬盘,点击高级,加载一下intel ICH10R raid的驱动就可以继续安装了。

有问题可以hi我。

另外,站长团上有产品团购,便宜有保证